Zdarec, na těch pár dní jsem používal fedoru, ale když jsem si stáhnul 2 filmy (z toho jeden 2krát) a vždicky mi to v několika místech hodilo chyba vstupu/výstupu, napadlo mě zkontrolovat disk.První co mě překvapilo, že ač jsem ďál několik testů, žádnej se nedostal přez 50%.
Tu je výpis z GSmartControl:
Tady je Error log:
Complete error log:
SMART Error Log Version: 1
ATA Error Count: 25713 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 25713 occurred at disk power-on lifetime: 1154 hours (48 days + 2 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
10 51 01 b0 ea 42 40 Error: IDNF at LBA = 0x0042eab0 = 4385456
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 01 40 b0 ea 42 40 00 00:03:02.300 READ FPDMA QUEUED
60 08 38 30 cc 61 40 00 00:03:02.300 READ FPDMA QUEUED
61 08 30 40 bb 6a 40 00 00:03:02.300 WRITE FPDMA QUEUED
60 20 28 c0 18 8d 40 00 00:03:02.300 READ FPDMA QUEUED
61 03 20 00 33 46 40 00 00:03:02.300 WRITE FPDMA QUEUED
Error 25712 occurred at disk power-on lifetime: 1154 hours (48 days + 2 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
10 51 01 b0 ea 42 40 Error: IDNF at LBA = 0x0042eab0 = 4385456
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 01 98 b0 ea 42 40 00 00:03:02.200 READ FPDMA QUEUED
60 08 90 80 25 7f 40 00 00:03:02.200 READ FPDMA QUEUED
60 40 88 3c 2f 77 40 00 00:03:02.200 READ FPDMA QUEUED
60 40 80 b4 2e 58 40 00 00:03:02.200 READ FPDMA QUEUED
60 21 78 58 e2 58 40 00 00:03:02.200 READ FPDMA QUEUED
Error 25711 occurred at disk power-on lifetime: 1154 hours (48 days + 2 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
10 51 01 b0 ea 42 40 Error: IDNF at LBA = 0x0042eab0 = 4385456
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 01 e8 b0 ea 42 40 00 00:03:02.100 READ FPDMA QUEUED
61 08 e0 40 bb 6a 40 00 00:03:02.100 WRITE FPDMA QUEUED
60 20 d8 c0 18 8d 40 00 00:03:02.100 READ FPDMA QUEUED
61 03 d0 00 33 46 40 00 00:03:02.100 WRITE FPDMA QUEUED
61 05 c8 38 54 15 40 00 00:03:02.100 WRITE FPDMA QUEUED
Error 25710 occurred at disk power-on lifetime: 1154 hours (48 days + 2 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
10 51 01 b0 ea 42 40 Error: IDNF at LBA = 0x0042eab0 = 4385456
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 01 98 b0 ea 42 40 00 00:01:50.500 READ FPDMA QUEUED
60 08 90 30 cc 61 40 00 00:01:50.500 READ FPDMA QUEUED
2f 00 01 10 00 00 40 00 00:01:50.500 READ LOG EXT
60 01 80 b0 ea 42 40 00 00:01:50.400 READ FPDMA QUEUED
60 08 78 30 cc 61 40 00 00:01:50.400 READ FPDMA QUEUED
Error 25709 occurred at disk power-on lifetime: 1154 hours (48 days + 2 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
10 51 01 b0 ea 42 40 Error: IDNF at LBA = 0x0042eab0 = 4385456
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 01 80 b0 ea 42 40 00 00:01:50.400 READ FPDMA QUEUED
60 08 78 30 cc 61 40 00 00:01:50.400 READ FPDMA QUEUED
2f 00 01 10 00 00 40 00 00:01:50.400 READ LOG EXT
60 01 68 b0 ea 42 40 00 00:01:50.300 READ FPDMA QUEUED
60 08 60 30 cc 61 40 00 00:01:50.300 READ FPDMA QUEUED
_______________________
a Self-testing log:
Complete selective self-test log:
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.